Activated Carbon Tower - Clean Air Treatment
Compressed Air Filters
Kaeser's Activated carbon Towers (KAT) are single tower pressure vessels filled with activated carbon adsorbent, that virtually eliminates oil vapor in compressed air. Other hydrocarbon vapors normally absorbable by activated carbon are also removed.
KAT's are used where oil vapor and odor contaminate end products such as food and drugs, or when the odor makes the environment uncomfortable.
Activated carbon works by adsorbing contaminants onto the surface of its internal pores. This process continues until it is saturated. When this occurs, the spent activated carbon should be removed and replaced.
Easy Installation
The KAT only requires piping connection for complete installation. For best performance, the KAT should be installed after a refrigerated air dryer. Using a Kaeser coalescing oil removal filter as a prefilter will greatly extend the life of the carbon bed. A Kaeser particulate filter installed after the KAT will prevent carbon dust and other solid contaminants from going downstream and harming equipment.
Engineering Data
Maximum Inlet Flow Capacities Table 1 lists the maximum inlet flow capacity at 100 psig. To determine maxi mum inlet flows at inlet pressures other than 100 psig, multiply the maximum flow from Table 1 by the multiplier from Table 2 that corresponds to the KAT inlet pressure.
Tower Sizing
At an inlet oil vapor concentration of 0.1 ppm w/w, the adsorber tower has a life of 30,000 hours at rated flow conditions. This concentration corresponds to air saturated with typical mineral oil at 75°F and 100 psig.
At an inlet oil vapor concentration of 0.35 ppm w/w, the adsorber tower has a life of 8,800 hours at rated flow conditions. This concentration corresponds to air saturated with typical mineral oil of 100°F and 100 psig.
KAT's are used where oil vapor and odor contaminate end products such as food and drugs, or when the odor makes the environment uncomfortable.
Activated carbon works by adsorbing contaminants onto the surface of its internal pores. This process continues until it is saturated. When this occurs, the spent activated carbon should be removed and replaced.
Easy Installation
The KAT only requires piping connection for complete installation. For best performance, the KAT should be installed after a refrigerated air dryer. Using a Kaeser coalescing oil removal filter as a prefilter will greatly extend the life of the carbon bed. A Kaeser particulate filter installed after the KAT will prevent carbon dust and other solid contaminants from going downstream and harming equipment.
Engineering Data
Maximum Inlet Flow Capacities Table 1 lists the maximum inlet flow capacity at 100 psig. To determine maxi mum inlet flows at inlet pressures other than 100 psig, multiply the maximum flow from Table 1 by the multiplier from Table 2 that corresponds to the KAT inlet pressure.
Tower Sizing
At an inlet oil vapor concentration of 0.1 ppm w/w, the adsorber tower has a life of 30,000 hours at rated flow conditions. This concentration corresponds to air saturated with typical mineral oil at 75°F and 100 psig.
At an inlet oil vapor concentration of 0.35 ppm w/w, the adsorber tower has a life of 8,800 hours at rated flow conditions. This concentration corresponds to air saturated with typical mineral oil of 100°F and 100 psig.
Item # |
Max. Flow at 100 psig |
Max. Working Pressure |
Dimensions (H x W x D) |
Connection Size (Inlet/Outlet) |
Connection Type (Inlet/Outlet) |
Weight |
---|---|---|---|---|---|---|
KAT 60 KAT 60/Asset/a1104.jpg | Max. Flow at 100 psig N/A 60 scfm | Max. Working Pressure N/A 250 psig | Dimensions (H x W x D) N/A 70 x 10 x 24 in. | Connection Size (Inlet/Outlet) N/A | Connection Type (Inlet/Outlet) N/A NPT | Weight N/A 68 lbs |
KAT 80 KAT 80/Asset/a1104.jpg | Max. Flow at 100 psig N/A 80 scfm | Max. Working Pressure N/A 250 psig | Dimensions (H x W x D) N/A 72 x 11 x 24 in. | Connection Size (Inlet/Outlet) N/A | Connection Type (Inlet/Outlet) N/A NPT | Weight N/A 89 lbs |
KAT 120 KAT 120/Asset/a1104.jpg | Max. Flow at 100 psig N/A 120 scfm | Max. Working Pressure N/A 250 psig | Dimensions (H x W x D) N/A 78 x 15 x 16 in. | Connection Size (Inlet/Outlet) N/A 1 in. | Connection Type (Inlet/Outlet) N/A NPT | Weight N/A 157 lbs |
KAT 190 KAT 190/Asset/a1104.jpg | Max. Flow at 100 psig N/A 190 scfm | Max. Working Pressure N/A 250 psig | Dimensions (H x W x D) N/A 60 x 17 x 18 in. | Connection Size (Inlet/Outlet) N/A 1 1/2 in. | Connection Type (Inlet/Outlet) N/A NPT | Weight N/A 176 lbs |
KAT 350 KAT 350/Asset/a1104.jpg | Max. Flow at 100 psig N/A 350 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 63 x 20 x 20 in. | Connection Size (Inlet/Outlet) N/A 1 1/2 in. | Connection Type (Inlet/Outlet) N/A NPT | Weight N/A 201 lbs |
KAT 500 KAT 500/Asset/a1104.jpg | Max. Flow at 100 psig N/A 500 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 64 x 22 x 22 in. | Connection Size (Inlet/Outlet) N/A 2 in. | Connection Type (Inlet/Outlet) N/A NPT | Weight N/A 271 lbs |
KAT 600 KAT 600/Asset/a1104.jpg | Max. Flow at 100 psig N/A 600 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 69 x 25 x 25 in. | Connection Size (Inlet/Outlet) N/A 3 in. | Connection Type (Inlet/Outlet) N/A NPT | Weight N/A 353 lbs |
KAT 800 KAT 800/Asset/a1104.jpg | Max. Flow at 100 psig N/A 800 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 70 x 27 x 27 in. | Connection Size (Inlet/Outlet) N/A 3 in. | Connection Type (Inlet/Outlet) N/A NPT | Weight N/A 415 lbs |
KAT 1000 KAT 1000/Asset/a1104.jpg | Max. Flow at 100 psig N/A 1000 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 72 x 29 x 29 in. | Connection Size (Inlet/Outlet) N/A 4 in. | Connection Type (Inlet/Outlet) N/A Flange | Weight N/A 474 lbs |
KAT 1250 KAT 1250/Asset/a1104.jpg | Max. Flow at 100 psig N/A 1250 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 73 x 31 x 31 in. | Connection Size (Inlet/Outlet) N/A 4 in. | Connection Type (Inlet/Outlet) N/A Flange | Weight N/A 604 lbs |
KAT 1500 KAT 1500/Asset/a1104.jpg | Max. Flow at 100 psig N/A 1500 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 73 x 33 x 33 in. | Connection Size (Inlet/Outlet) N/A 4 in. | Connection Type (Inlet/Outlet) N/A Flange | Weight N/A 662 lbs |
KAT 1800 KAT 1800/Asset/a1104.jpg | Max. Flow at 100 psig N/A 1800 scfm | Max. Working Pressure N/A 180 psig | Dimensions (H x W x D) N/A 74 x 36 x 35 in. | Connection Size (Inlet/Outlet) N/A 4 in. | Connection Type (Inlet/Outlet) N/A Flange | Weight N/A 741 lbs |
KAT 2100 KAT 2100/Asset/a1104.jpg | Max. Flow at 100 psig N/A 2100 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 80 x 37 x 37 in. | Connection Size (Inlet/Outlet) N/A 4 in. | Connection Type (Inlet/Outlet) N/A Flange | Weight N/A 1136 lbs |
KAT 2800 KAT 2800/Asset/a1104.jpg | Max. Flow at 100 psig N/A 2800 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 79 x 42 x 42 in. | Connection Size (Inlet/Outlet) N/A 4 in. | Connection Type (Inlet/Outlet) N/A Flange | Weight N/A 1279 lbs |
KAT 4000 KAT 4000/Asset/a1104.jpg | Max. Flow at 100 psig N/A 4000 scfm | Max. Working Pressure N/A 200 psig | Dimensions (H x W x D) N/A 84 x 48 x 59 in. | Connection Size (Inlet/Outlet) N/A 6 in. | Connection Type (Inlet/Outlet) N/A Flange | Weight N/A 1840 lbs |
KAT 5500 KAT 5500/Asset/a1104.jpg | Max. Flow at 100 psig N/A 5500 scfm | Max. Working Pressure N/A 180 psig | Dimensions (H x W x D) N/A 88 x 54 x 65 in. | Connection Size (Inlet/Outlet) N/A 6 in. | Connection Type (Inlet/Outlet) N/A Flange | Weight N/A 2578 lbs |