Flow Capacities Maximum inlet flow capacities at various pressures: To determine a dryer's inlet flow capacity at inlet pressures other than 100 psig, multiply the dryer's rated inlet flow (found in Table 1) by the multiplier from Table 2 that corresponds to the system pressure at the dryer inlet. KAD Dew Point Options Meet ISO 8573.1 Air Quality Standards (Table 3) Models KAD and KAD PS allow the user to select outlet pressure dew points corresponding to the four different ISO 8573.1 air quality classes. KAD E models are preset to deliver the commonly used ISO 8573.1 Class 2 outlet pressure dew point. Outlet flow capacities: For dryers operating at less than maximum flow and using the Purge Economizer feature and/or operating at pressures other than 100 psig, contact factory for correct purge flow. -
Average Heater kW (fixed cycle) = (kW required to produce 280°F temperature rise) x (235 min. max heat time) / (240 min. drying time) Actual kW is normally much lower and proportional with the average annual water load presented to the dryer.
Unit of Measure
Specifications
Manufacturer
N/A Kaeser
Product Family
N/ADesiccant Dryers
Series
N/AKED
Inlet Flow at 100 psig 100ºF
N/A2600 scfm
Width
N/A85 in.
Depth
N/A73 in.
Height
N/A128 in.
Connection Size (Inlet/Outlet)
N/A4 in.
Connection Type (Inlet/Outlet)
N/AFlange
Weight
N/A7753 lbs
Purge Flow Rate
N/A182 scfm
Air Available Average
N/A2418
Nom. Heater
N/A33 kW
Avg. Heater
N/A17.4 kW
Pre-Filter (KOR Series)
N/A3125P
High Temp After-Filter (HTA Series)
N/A3000
Desiccant Per Tower
N/A1867
Other Options
N/ADew point monitor High humidity alarm Insulation for heated desiccant air dryers NEMA 4 low ambient protection packages Parallel piped pre-filters and after-filters Stainless steel or copper pilot and instrument air tubing and fittings