Print Back
Flow Capacities Maximum inlet flow capacities at various pressures:
To determine a dryer's inlet flow capacity at inlet pressures other than 100 psig, multiply the dryer's rated inlet flow (found in Table 1) by the multiplier from Table 2 that corresponds to the system pressure at the dryer inlet.
KAD Dew Point Options Meet ISO 8573.1 Air Quality Standards (Table 3)
Models KAD and KAD PS allow the user to select outlet pressure dew points corresponding to the four different ISO 8573.1 air quality classes.
KAD E models are preset to deliver the commonly used ISO 8573.1 Class 2 outlet pressure dew point.
Outlet flow capacities:
For dryers operating at less than maximum flow and using the Purge Economizer feature and/or operating at pressures other than 100 psig, contact factory for correct purge flow.
PI - Regenerative Desiccant Dryers
Unit of Measure
Items PI - Regenerative Desiccant Dryers
KED 300
Kaeser Heated Purge Dryers - KED Series
PI - Regenerative Desiccant Dryers
KED 400
Kaeser Heated Purge Dryers - KED Series
PI - Regenerative Desiccant Dryers
KED 500
Kaeser Heated Purge Dryers - KED Series
PI - Regenerative Desiccant Dryers
KED 600
Kaeser Heated Purge Dryers - KED Series
PI - Regenerative Desiccant Dryers
KED 750
Kaeser Heated Purge Dryers - KED Series
Manufacturer N/A Kaeser
Product Family N/A Desiccant Dryers
Series N/A KED
Inlet Flow at 100 psig 100ºF N/A 300 scfm N/A 400 scfm N/A 500 scfm N/A 600 scfm N/A 750 scfm
Dimensions (W x D x H) N/A 48 x 46 x 98 in. N/A 53 x 52 x 104 in. N/A 53 x 52 x 105 in. N/A 55 x 53 x 108 in. N/A 60 x 59 x 114 in.
Width N/A 48 in. N/A 53 in. N/A 53 in. N/A 55 in. N/A 60 in.
Depth N/A 46 in. N/A 52 in. N/A 52 in. N/A 53 in. N/A 59 in.
Height N/A 98 in. N/A 104 in. N/A 105 in. N/A 108 in. N/A 114 in.
Connection Size (Inlet/Outlet) N/A 1 1/2 in. N/A 1 1/2 in. N/A 2 in. N/A 2 in. N/A 3 in.
Connection Type (Inlet/Outlet) N/A NPT N/A NPT N/A NPT N/A NPT N/A Flange
Weight N/A 1360 lbs N/A 1776 lbs N/A 1776 lbs N/A 1978 lbs N/A 2323 lbs
Purge Flow Rate N/A 21 scfm N/A 28 scfm N/A 35 scfm N/A 42 scfm N/A 53 scfm
Air Available Average N/A 279 N/A 372 N/A 465 N/A 558 N/A 697
Nom. Heater N/A 5 kW N/A 7 kW N/A 7 kW N/A 8 kW N/A 10 kW
Avg. Heater N/A 2.0 kW N/A 2.7 kW N/A 3.3 kW N/A 4.0 kW N/A 5.0 kW
Pre-Filter (KOR Series) N/A 375 N/A 625 N/A 625 N/A 780 N/A 1000P
High Temp After-Filter (HTA Series) N/A 400 N/A 600 N/A 600 N/A 1200 N/A 1200
Desiccant Per Tower N/A 210 N/A 354 N/A 354 N/A 453 N/A 590
Other Options N/A Dew point monitor High humidity alarm Insulation for heated desiccant air dryers NEMA 4 low ambient protection packages Parallel piped pre-filters and after-filters Stainless steel or copper pilot and instrument air tubing and fittings