Flow Capacities Maximum inlet flow capacities at various pressures:
To determine a dryer's inlet flow capacity at inlet pressures other than 100 psig, multiply the dryer's rated inlet flow (found in Table 1) by the multiplier from Table 2 that corresponds to the system pressure at the dryer inlet.
KAD Dew Point Options Meet ISO 8573.1 Air Quality Standards (Table 3)
Models KAD and KAD PS allow the user to select outlet pressure dew points corresponding to the four different ISO 8573.1 air quality classes.
KAD E models are preset to deliver the commonly used ISO 8573.1 Class 2 outlet pressure dew point.
Outlet flow capacities:
For dryers operating at less than maximum flow and using the Purge Economizer feature and/or operating at pressures other than 100 psig, contact factory for correct purge flow.
PI - Regenerative Desiccant Dryers
Unit of Measure
Items PI - Regenerative Desiccant Dryers
KBD 500
Kaeser Blower Purge Dryers - KBD Series
PI - Regenerative Desiccant Dryers
KBD 600
Kaeser Blower Purge Dryers - KBD Series
PI - Regenerative Desiccant Dryers
KBD 750
Kaeser Blower Purge Dryers - KBD Series
PI - Regenerative Desiccant Dryers
KBD 900
Kaeser Blower Purge Dryers - KBD Series
PI - Regenerative Desiccant Dryers
KBD 1050
Kaeser Blower Purge Dryers - KBD Series
Manufacturer N/A Kaeser
Product Family N/A Desiccant Dryers
Series N/A KBD
Inlet Flow at 100 psig 100ºF N/A 500 scfm N/A 600 scfm N/A 750 scfm N/A 900 scfm N/A 1050 scfm
Dimensions (W x D x H) N/A 53 x 52 x 105 in. N/A 55 x 60 x 108 in. N/A 60 x 68 x 114 in. N/A 60 x 68 x 114 in. N/A 64 x 62 x 113 in.
Width N/A 53 in. N/A 55 in. N/A 60 in. N/A 60 in. N/A 64 in.
Depth N/A 52 in. N/A 60 in. N/A 68 in. N/A 68 in. N/A 62 in.
Height N/A 105 in. N/A 108 in. N/A 114 in. N/A 114 in. N/A 113 in.
Connection Size (Inlet/Outlet) N/A 2 in. N/A 2 in. N/A 3 in. N/A 3 in. N/A 3 in.
Connection Type (Inlet/Outlet) N/A NPT N/A NPT N/A Flange N/A Flange N/A Flange
Weight N/A 1776 lbs N/A 1861 lbs N/A 2429 lbs N/A 2445 lbs N/A 2966 lbs
Nom. Heater N/A 10 kW N/A 12 kW N/A 14 kW N/A 17 kW N/A 19 kW
Avg. Heater N/A 6.4 kW N/A 7.7 kW N/A 9.6 kW N/A 10.8 kW N/A 12.5 kW
Pre-Filter (KOR Series) N/A 625 N/A 780 N/A 1000P N/A 1250P N/A 1875P
High Temp After-Filter (HTA Series) N/A 600 N/A 1200 N/A 1200 N/A 1200 N/A 1200
Desiccant Per Tower N/A 354 N/A 453 N/A 590 N/A 590 N/A 710
Blower Flow Rate N/A 94 scfm N/A 113 scfm N/A 140 scfm N/A 158 scfm N/A 183 scfm
Nom. Blower N/A 2.5 N/A 4 N/A 4 N/A 4 N/A 5
Avg. Blower N/A 1.6 N/A 2.5 N/A 2.2 N/A 2.0 N/A 2.6
Other Options N/A Dew point monitor High humidity alarm Insulation for heated desiccant air dryers NEMA 4 low ambient protection packages Parallel piped pre-filters and after-filters Stainless steel or copper pilot and instrument air tubing and fittings