Kaeser Blower Purge Dryers - KBD Series
Desiccant Dryers
Flow Capacities Maximum inlet flow capacities at various pressures:
To determine a dryer's inlet flow capacity at inlet pressures other than 100 psig, multiply the dryer's rated inlet flow (found in Table 1) by the multiplier from Table 2 that corresponds to the system pressure at the dryer inlet.
KAD Dew Point Options Meet ISO 8573.1 Air Quality Standards (Table 3)
Models KAD and KAD PS allow the user to select outlet pressure dew points corresponding to the four different ISO 8573.1 air quality classes.
KAD E models are preset to deliver the commonly used ISO 8573.1 Class 2 outlet pressure dew point.
Outlet flow capacities:
For dryers operating at less than maximum flow and using the Purge Economizer feature and/or operating at pressures other than 100 psig, contact factory for correct purge flow.
To determine a dryer's inlet flow capacity at inlet pressures other than 100 psig, multiply the dryer's rated inlet flow (found in Table 1) by the multiplier from Table 2 that corresponds to the system pressure at the dryer inlet.
KAD Dew Point Options Meet ISO 8573.1 Air Quality Standards (Table 3)
Models KAD and KAD PS allow the user to select outlet pressure dew points corresponding to the four different ISO 8573.1 air quality classes.
KAD E models are preset to deliver the commonly used ISO 8573.1 Class 2 outlet pressure dew point.
Outlet flow capacities:
For dryers operating at less than maximum flow and using the Purge Economizer feature and/or operating at pressures other than 100 psig, contact factory for correct purge flow.
Unit of Measure
Items |
/Asset/a1117.jpg KBD 500 Kaeser Blower Purge Dryers - KBD Series |
/Asset/a1117.jpg KBD 600 Kaeser Blower Purge Dryers - KBD Series |
/Asset/a1117.jpg KBD 750 Kaeser Blower Purge Dryers - KBD Series |
/Asset/a1117.jpg KBD 900 Kaeser Blower Purge Dryers - KBD Series |
/Asset/a1117.jpg KBD 1050 Kaeser Blower Purge Dryers - KBD Series |
|||||
Manufacturer |
N/A
Kaeser |
|||||||||
Product Family | N/A Desiccant Dryers | |||||||||
Series | N/A KBD | |||||||||
Inlet Flow at 100 psig 100ºF | N/A 500 scfm | N/A 600 scfm | N/A 750 scfm | N/A 900 scfm | N/A 1050 scfm | |||||
Dimensions (W x D x H) | N/A 53 x 52 x 105 in. | N/A 55 x 60 x 108 in. | N/A 60 x 68 x 114 in. | N/A 60 x 68 x 114 in. | N/A 64 x 62 x 113 in. | |||||
Width | N/A 53 in. | N/A 55 in. | N/A 60 in. | N/A 60 in. | N/A 64 in. | |||||
Depth | N/A 52 in. | N/A 60 in. | N/A 68 in. | N/A 68 in. | N/A 62 in. | |||||
Height | N/A 105 in. | N/A 108 in. | N/A 114 in. | N/A 114 in. | N/A 113 in. | |||||
Connection Size (Inlet/Outlet) | N/A 2 in. | N/A 2 in. | N/A 3 in. | N/A 3 in. | N/A 3 in. | |||||
Connection Type (Inlet/Outlet) | N/A NPT | N/A NPT | N/A Flange | N/A Flange | N/A Flange | |||||
Weight | N/A 1776 lbs | N/A 1861 lbs | N/A 2429 lbs | N/A 2445 lbs | N/A 2966 lbs | |||||
Nom. Heater | N/A 10 kW | N/A 12 kW | N/A 14 kW | N/A 17 kW | N/A 19 kW | |||||
Avg. Heater | N/A 6.4 kW | N/A 7.7 kW | N/A 9.6 kW | N/A 10.8 kW | N/A 12.5 kW | |||||
Pre-Filter (KOR Series) | N/A 625 | N/A 780 | N/A 1000P | N/A 1250P | N/A 1875P | |||||
High Temp After-Filter (HTA Series) | N/A 600 | N/A 1200 | N/A 1200 | N/A 1200 | N/A 1200 | |||||
Desiccant Per Tower | N/A 354 | N/A 453 | N/A 590 | N/A 590 | N/A 710 | |||||
Blower Flow Rate | N/A 94 scfm | N/A 113 scfm | N/A 140 scfm | N/A 158 scfm | N/A 183 scfm | |||||
Nom. Blower | N/A 2.5 | N/A 4 | N/A 4 | N/A 4 | N/A 5 | |||||
Avg. Blower | N/A 1.6 | N/A 2.5 | N/A 2.2 | N/A 2.0 | N/A 2.6 | |||||
Other Options | N/A Dew point monitor High humidity alarm Insulation for heated desiccant air dryers NEMA 4 low ambient protection packages Parallel piped pre-filters and after-filters Stainless steel or copper pilot and instrument air tubing and fittings | |||||||||
|